#======== Film grain characteristics SEI message ===================== SEIFGCEnabled : 1 # enable to use FGC SEI message. SEIFGCAnalysisEnabled : 0 # enable film grain analysis to estimate grain parameters. SEIFGCCancelFlag : 0 # for SMPTE-RDD5: the value must be 0 SEIFGCPersistenceFlag : 1 # for SMPTE-RDD5: the value must be 0; When FGC SEI frequency is once per I-period (SEIFGCPerPictureSEI is 0), than SEIFGCPersistenceFlag 1 SEIFGCPerPictureSEI : 0 # for SMPTE-RDD5: the value must be 1 (0: FGC SEI is inserted once per I-period; 1: FGC SEI is inserted once per picture) SEIFGCModelID : 0 # for SMPTE-RDD5: the value must be 0 (0: frequency filtering; 1: auto-regression; 2-3 are reserved) SEIFGCSepColourDescPresentFlag : 0 # for SMPTE-RDD5: the value must be 0 (if not 0, need to specify separate colour description (not implemented in current encoder cmd line)) SEIFGCBlendingModeID : 0 # for SMPTE-RDD5: the value must be 0 (0: additive; 1: multipliciative) SEIFGCLog2ScaleFactor : 2 SEIFGCCompModelPresentComp0 : 1 # if not 0, need to specify model for comp 0; otherwise default parameters will be used. SEIFGCCompModelPresentComp1 : 1 # if not 0, need to specify model for comp 1; otherwise default parameters will be used. SEIFGCCompModelPresentComp2 : 1 # if not 0, need to specify model for comp 2; otherwise default parameters will be used. SEIFGCNumIntensityIntervalMinus1Comp0 : 0 # Number of intensity intervals minus 1 for comp 0 SEIFGCNumIntensityIntervalMinus1Comp1 : 0 # Number of intensity intervals minus 1 for comp 1 SEIFGCNumIntensityIntervalMinus1Comp2 : 0 # Number of intensity intervals minus 1 for comp 2 SEIFGCNumModelValuesMinus1Comp0 : 2 # Number of model values minus 1 for comp 0 SEIFGCNumModelValuesMinus1Comp1 : 2 # Number of model values minus 1 for comp 1 SEIFGCNumModelValuesMinus1Comp2 : 2 # Number of model values minus 1 for comp 2 SEIFGCIntensityIntervalLowerBoundComp0 : 10 # Lower bound of intensity interval for comp 0 (for SMPTE-RDD5, non-overlapping interval) SEIFGCIntensityIntervalLowerBoundComp1 : 60 # Lower bound of intensity interval for comp 1 (for SMPTE-RDD5, non-overlapping interval) SEIFGCIntensityIntervalLowerBoundComp2 : 60 # Lower bound of intensity interval for comp 2 (for SMPTE-RDD5, non-overlapping interval) SEIFGCIntensityIntervalUpperBoundComp0 : 250 # Upper bound of intensity interval for comp 0 (for SMPTE-RDD5, non-overlapping interval) SEIFGCIntensityIntervalUpperBoundComp1 : 200 # Upper bound of intensity interval for comp 1 (for SMPTE-RDD5, non-overlapping interval) SEIFGCIntensityIntervalUpperBoundComp2 : 250 # Upper bound of intensity interval for comp 2 (for SMPTE-RDD5, non-overlapping interval) SEIFGCCompModelValuesComp0 : 16 8 8 # model values for each intensity interval for comp 0 (sigma, h, v (h,v might be inferred based on number of model value)) SEIFGCCompModelValuesComp1 : 24 12 12 # model values for each intensity interval for comp 1 (sigma, h, v (h,v might be inferred based on number of model value)) SEIFGCCompModelValuesComp2 : 40 3 3 # model values for each intensity interval for comp 2 (sigma, h, v (h,v might be inferred based on number of model value))